logo logo

Antminer frequency setting

Your Choice. Your Community. Your Platform.

  • shape
  • shape
  • shape
hero image


  • Compared with the Antminer S7s from the previous generation, the Antminer S9s showcase significant energy efficiency improvements, transitioning from 0. Best Regards. Would I make more money if I overclock it to 450 frequency producing MH at 600? Or do I get paid the same no matter what MH? Thank you. Jan 1, 2019 · I went to the advanced configuration menu and set the "Search Frequency From" to 662. May 3, 2018 · Miner cannot connect mining pools >. Whether you bought your ASIC miner new or second hand I will teach you exactly how to get it up and running as Oct 2, 2018 · OC AsicBoost Antminer S9, T9+ Bmminer - Deploy Tool and access to set freq, volt, Fan Disable The guy on discord used 750 frequency, but temp was 100 deg, a bit So you set it to 9. ANTMINER Please note: 1. Ensure the working area has good airflow for ventilation. The overclocked device hashrate is ~500GH/s at 250MHz. Setting Up Bitmain Antminer S17e Server. AntMiner S7 Manual User Guide. This runs at absolute minimum and the fan speed is audible but not disrupting. Connecting the Power Supply Ten PCI-e connectors are located at the top of the AntMiner T9 for connecting the PSU as follows: Nine PCI-e connectors for the hash boards. First, get your PSU ready. So to recap: 1. ) I loaded the 650M fixed frequency firmware into my autotune unit. AntSpace HK3 V2 Water Cooling Container Safety Instructions. You need to prepare a PSU > 1300w with 6pin x 10 for the miner. Apr 18, 2018 · Miner has no mining program >. 2 Modifying the Frequency You are able to modify the frequency value through ‘Miner Configuration —>Advanced Settings’. Jan 5, 2018 · Some startup settings to get you going: stock speeds @ low power -> silenced and improved miner lifetime (my personal preference) Expected hashrate: 480MH/s to 540 MH/s Expected power usage: 600 - 770 watt set the global frequency at "375" and increase upto 425mhz (depends per unit how far it clocks stable), set the global voltage to "lowest". Title. 99, [code] [b]Username:root, Pwd:root [/b] Overclocking. ligunov@gmail. The AntMiner S5 is Bitmain's 5th generation of Bitcoin mining rig and uses the state of the art BM1384 chip powered by ultra-low power 28nm technology. One of BITMAIN’s most recent models is the Antminer E9 server. Mar 26, 2015 · 5. 0)--api-allow < arg > Allow API access only to the given list of [G:] IP [/Prefix] addresses [/subnets]--api-description < arg > Description placed in the API status header, default: cgminer version--api-groups < arg > API one letter groups G:cmd:cmd [, P:cmd: *] defining the cmds a groups can use--api-listen Lower the frequency and increase the voltage. The default username and password are "root". 6 - 13 V. ASI#: Number of chips detected in the chain Frequency: ASI frequency setting GH/S(RT): Hash rate of each hash board 4. and 2. 1 The AntMiner S4+ can be set up with three mining pools, with decreasing priority from the first pool (pool 1) to the third pool (pool 3). 6 Miner Status You can check the operating status of your miner on Miner Status [ page. Connect miner and your PC via network cable. (America!) 4. Miner has no mining program >. Note: Fan speed percentage can be adjusted, but we recommend to keep the default setting. It is the most essential part of the mining hardware, as when kept under the required temperature conditions, it performs well. It is best to tweak antminer z9 overclocking settings with fans set to 100%. 1 W/Gx/s. ) I changed the frequency to 662. Mar 24, 2018 · The connection of the Antminer A3 is exactly the same with other Antminer. 5T±5% 14T±5% 14. I currently bought a used antminer L3+. Can't power on the miner (non-integrated miner). I have found minimal hardware errors with this setting, averaging <1 per hour overall. The Antminer machine in our example was able to generate an average hashpower of 4074. May 31, 2016 · In the dynamic realm of Bitcoin mining, the introduction of the Antminer S9 by Bitmain marked a pivotal moment, setting new standards for efficiency and performance. 1 LTC a day on ltcpool. 1. I also have a Z9mini @ 16Ksol/s on viabtc mining ZEN, getting about 0. 015 ZEN a day. The voltage range of the officially released T9+ should be 11. Obtain IP Address: Access your router's admin panel and find the list of connected devices. Step 3. HW errors are a normal part of mining. Start tweaking some more. Step 2. PSU output power is recommended to be 20% higher than the power consumption of miner; 2. 25 W/Gx/s to 0. Bitmain recommend a default frequency of AntMiner D3, and Overlocking the miner will void the warranty immediately. In Addition to Frequency Adjustment There is Also a Power Limit Setting. conf in your folder of choice. Sleep Mode: Mining can stop and fans drop to normal speed using very little power. You can do this by checking your router's DHCP client list or using network scanning tools. PSU/Power. The power capacity and infrastructure for any ASIC miner are relatively high. In Miner Configuration, click General Settings. For details, please refer to "FAQ——Account Registration" 2. Small 3% fee to keep the project going. You'd need to measure power draw and hashrate with Sep 23, 2015 · Power on miner and let it run for 5 minutes, then press and hold the reset button for 10 seconds in order to restore to the default settings and reboot. Identify the Antminer K7 and note down its IP address. One PCI-e connector located on the controller. Storage Temperature, °C. *Notes: 1. Then click “ Save&Apply ” to connect to the mining pools. To configure the server: click “Setting” marked below. Remember, the key to Apr 2, 2019 · Miner cannot be powered on >. Apr 13, 2024 · 4. A dialog box will pop up and ask for login credentials. Stable: Automated voltage tuning for best hashboard stability and performance. E9 server includes the power supply APW12. Miner cannot connect to Internet >. Reset miner to factory settings >. *Note: Fan speed percentage can be adjusted, but we recommend to keep the default setting. 2 Modifying the Frequency (Applied only to fixed frequency firmware) To modify the frequency value: In Miner Configuration, click Advanced Settings; Select a frequency. The router or network switch you are using to get connected with miners shall be ones without K!6!K! AntMiner!L3+!Installation!Guide! 1!. cash when they are on sale Antminer L3 + 504MH Ready to buy more expensive. Determine the IP address of your Antminer L7. The default frequency for the L3+ server is 384M --‐ 12 - -‐ Page 13: Monitoring Your Server Jan 19, 2020 · Once you open the program on your computer, press start and press the "IP Report" button on the V9. Place the Antminer in an aerated place, as the machine will exhaust a lot of heat. From there increase your frequency to see how high you can go at the lowest voltage setting. Internal testing shows that for the Antminer S9, it’s possible to achieve efficiency of 70J/THs or even better for low Watts setting. In Antminer installation tutorial article, we will teach you how to set up Ant-Miner S9 and S17. making sure other clock speeds are commented out. com. For the miner configuration, please connect the miner to the LAN port on the same router which your computer is also connected to. Set your new password, then click Save & Apply. In our illustration, the Antminer device was set to operate at a frequency of 600. You must prepare your own AT)( Power Supply 12. Ensure that there is sufficient space between mining rigs to prevent overheating. Below are three M30S++ 110T models that have had their frequency and power limits Nov 13, 2018 · ANTMINER T15 Created November 13, 2018 08:16; Updated February 15, 2022 06:56; Follow Reset miner to factory settings > Fan speed low or not spinning > T9+ is an automatic frequency miner. To check the operating status of your server: Jun 30, 2021 · Setting Up the Pool. Antminer S9 Frequency. Long-term of stable operation and the measured average hashrate is about 593M, the power is 1040w. It is evident that Bitmain also has people looking to mine at home in mind. You will see that there is a commented option for Turbo set at 550 MHz as a value, you can edit this one by removing the commenting brackets at the start and end of the line or even just change the frequency Nov 29, 2023 · It is 430 x 195 x 290 mm in dimension and weighs 16100 g—the noise level of the Bitmain Antminer KS3 is 75. Check that you are using two C13 power connectors and connect them to 220V AC outlet. Miner not hashing or low hash rate >. There's no need to change the password. Operation humidity (non-condensing), RH. The default frequency for the AntMiner R4 is 600M. PSU Problems and Solutions(apply to APW9/APW12). Supports popular ASICs: Support for all Antminer S17/T17 ,S9/S9i/S9j models. Make sure the connection is secure. Power on miner and let it run for 5 minutes, then press and hold the reset button for 10 seconds in order to restore to the default settings and reboot. To power up your L3+ server, connect the PSUs to the power wall outlet. 4 Restoring Initial Settings To restore your initial settings. The higher the frequency, the faster the mining process. Chains 2/4 are set to voltage setting 2. 1 Setting Up the Pool To configure the miner: 1. I set the global frequency to 387 for a safe light overclock. The socket outlet must be installed close to the machinery and be Oct 9, 2023 · 2. Cannot detect IP of miner >. Aug 25, 2023 · 4. Page 12: Modifying The Frequency AntMinerD3InstallationGuide 4. In my setup, I have my antminer_slow file set with fan speed 15%, and frequency 100. Mar 21, 2019 · Hash rate: 13T±5% 13. button for 10 seconds. On the controller front panel, press and hold the . 50 2 Features Ideal Hash Rate We would like to show you a description here but the site won’t allow us. 1%. You are able to modify the frequency value through ZMiner onfiguration->Advanced Settings [. Operation Humidity (non-condensing), RH. Using the miner. 93T-600M, 14T-650M. To ensure simple setup, all E9 servers are tested and configured before shipping. Stanislav. If ASIC# number is 100 and in the ASIC status the number of ”0”s is less than 100, it means some chips are missing or cannot be detected. ) So, we now have a baseline of 504 MH/s (126 MH/s for each hash board). Overview !!!! Feature(!Description(!IdealHashRate! 504MH/S! Default!chip!frequency! 384M! Estimated!wall!outlet!power! Nov 26, 2013 · Manually set up your PC’s IP address in the network segment same as the miner’s IP address. tnx. Nov 1, 2017 · Flash by going to "System" -> "Upgrade" -> "Flash new firmware image" and select the custom firmware. Let’s continue using the base Antminer L3+ with its default factory firmware and default settings. Nov 30, 2021 · Antminer L3+ Blissz Firmware Tuning ASIC Mining. Increasing the frequency can lead to higher hash rates, but it also increases power consumption and heat output. You can overclock the S3 to 250MHz by first ssh'ing into the device, and then uncomment the 250M clock speed lines and. 3. Currently I use the firmware called vnish, and I can boost the frequency and voltage. Lastly, the humidity and temperature of the Antminer KS3 are 10-90% and 5-40 Degrees Celsius, respectively. Using L3+ as an example, we will demonstrate the operational process of mining with our AntMiner. If you are running the native frequency of 384, or even 400, turn it down a bit until you get that % under 0. LuxOS: Allows for extensive customization, including fine-tuning of power limits and frequency settings, leading to improved hashrate and potential for higher profitability. The pools with low priority will only be used if all higher priority pools have gone offline. 2 When ‘Stop running when temperature is over 95°C’ is checked, the miner will stop mining when the How to set up S19 Pro+ Hydro Server? How to set up E9 Server? How to set up Z15 Server? AntSpace HK3 V2 Container System Power-on and Power-off Process. 5 And Now 2. 5M and steady hashing at 14. S9 has three hash board versions: 11. com Apr 1, 2022 · Tweaking Settings for Optimal Performance. I have been operating a few M30S++ at a -30% frequency, and I am getting around 27 W/TH. -20-70. 5 TH/s stock setting with ~ 94J/TH). 4/21=0. The frequency of an Antminer S9 refers to the speed at which it performs calculations to mine cryptocurrencies. The default DHCP network protocol distributes IP addresses automatically. Keywords. There are two working modes of 19 series server: Normal mode and Sleep mode. Oct 8, 2023 · Storage temperature, °C. AntMiner S5 Manual. Make a note of the frequency that is set on your Antminer device. There really is no underclocking then since when you set the voltage it sets that for each of the 21 lanes. Hello folks, I’m currently running blissz firware on my L3+ miners with a frequency range of 400 + voltage of 6 and seeing about 523 MH/s with minimal hardware errors. Voltage has been set to setting 1 on chains 1/3. 82TH/s Power consumption: N/A Fan Speed: 35% Avg Blade Temperature: 54C Hardware Errors Per Day: 3/day Antminer Models. In my case, it's saved in "antminer_slow". Turn on the server and let it run for 5 minutes. Apr 9, 2019 · Click the “ Miner Configuration ” tab to set up the mining pools. 00M. Monitor the board for at least 10 minutes to make sure it is stable. Antminer Distribution Europe BV Nov 11, 2023 · Adjust the Frequency Settings: By following these tips and continuously monitoring and adjusting your settings, you can ensure that your Antminer S19 operates at its best. Configuring the Server 4. Meanwhile, mastering simple fault judgment methods, such as high-temperature protection, fan fault, network May 3, 2022 · How to set up your L3 Antminers from Bitmain. On your computer, type the displayed IP address into a browser. The Antminer L3++ has a low power consumption rate. Enter miner’s IP address into your web browser, then login miner management interface, both of username and password is ‘root’ by default. Dec 21, 2021 · Frequency is constant at 550 MHz and the voltage is constant at 13. Monitoring Bitmain Antminer L3+ Server. Setp 4. Reset . 5 hash boards, that gives us an operating frequency of 384MHz and a voltage of 10. I have an L3+ and a L3++ overclocked to 690MH each (~1. The red LED will Apr 24, 2017 · Send a message to mail: bismuth@forum. ASIC chips are all 0. ANTPOOL account registration and configuration. 2v and 687 frequency is normal, with…. With certain overclocking space (depending on actual condition of every miner). Download the following file: IPReporter. Testing each hash board >. org:3333. 5T±5% Frequency: Auto Fan: 2 fans @ 12 V and 2. ckpool. 5V. Given this setup, I can power up to three S17+ AntMiners per PDU. Fan speed low or not spinning >. Extract the file. AntSpace HK3 V2 Water-cooling System Usage and Operation. Below are the key specifications of the Antminer L3+: Hash Rate: It delivers a hash rate of 504 MH/s, which is a measure of the number of hashing operations the miner can perform in a second. Mar 11, 2021 · Repeat this cycle until you have a stable minimum frequency for your boards. S5's are tested and configured prior to shipping to make it easier for customers to set up. 1. These include adjusting the frequency settings, optimizing the cooling system, and fine-tuning the power usage. Comment actions. Nov 17, 2022 · 0~40. Nov 29, 2015 · Frequency: Freq# Hashrate: Hashrate# Power consumption: PowerConsumption# (If possible) Fan Speed: FanSpeedPercentage# Avg Blade Temperature: TempInCelcius# Hardware Errors Per Day: HWerrors# For example: Batch: 6 Frequency: 575 Hashrate: 3. Resetting your server will reboot it and restore its default settings. I’m trying to be efficient with mining while using less power but not 100% familiar with tuning on these machines. Feb 22, 2019 · Summary. My e-mail is: tagooba@gmail. Pulling in 0. The cord connects the PDU to the PSU attached to the AntMiner. Accessing the Web Interface. May 24, 2023 · Connect the power supply and Ethernet cable to the miner. The AntMiner D3 can be set up with three mining pools, with decreasing priority from the first pool (pool 1) to the third pool Sep 13, 2018 · What you have to do is hover the drop-down box where only Balance is available and right click on it selecting Inspect or Inspect Element. As the digital gold rush intensified, the demand for more powerful and energy-efficient mining hardware led to significant technological advancements. 8V. Feb 7, 2021 · n this video, we'll show you how to set up and overclock your L3+ Litecoin miner for maximum performance and profitability. Navigate to the “Miner Configuration” or “Pool Settings” tab. Each occupies two C13 sockets. APW11 PSU Replacement Instructions. Each hash board has a set of three PCI-e connectors. Apr 15, 2020 · Free – Download and begin using immediately. To set up the server: The file IPReporter. Been running on this setting for almost a year now. Dec 12, 2018 · Normal status: “0” means normal, you should find 63 (or the number of chips in your specific miner) “0”s in this field. -20~70. Enter the CKPool’s URL and port number in the “URL” field. It is possible to damage the miner if you use a high frequency setting, and also please make sure the miner is in a good situation and the capacity of power supply is enough before you apply a over frequency setting. Nov 6, 2023 · Step-by-step guide for setting up the Antminer S19K Pro 120T. Choose from work modes (S17 Pro has three modes/S17 has two modes) Low Power, Normal, and Turbo. If you are trying to underclock it for better efficiency you would need to recompile bminer and lower the voltage to whatever works best for whatever frequency your using. 168. Antminer Litecoin L3++ is the optimized and upgraded version of L3+, and the hashrate of single miner is increased by about 90M. 85T-550M, 12. Power on the Antminer L7 and wait for it to initialize. Learn how to configure antminer overclocking, by following this simple step-by-step tutorial, you will overclock antminer in 5 minutes. The red LED will flash once every 15 seconds automatically if the reset is operated successfully. By choosing and configuring the right software, miners can significantly enhance the performance of their Antminer S19 units. As a result of the fixed frequency settings, hashrate is constant for all data points in the chart. Shutting down the miner >. To start “upstream tuning”, select one board and increase its frequency by 1 step. 4GH). 2 Modifying the Frequency (Applied only to fixed frequency firmware) To modify the frequency value: click Advanced Settings Select a frequency. Here we will take Bitmain Antminer L3+ as an example to introduce how to set up the miner and start to mine Bitcoin. Power-on and Power-off Guidance for the 19 Series PSU. Mar 18, 2018 · Miner cannot connect mining pools >. See all 10 articles. zip. The automatic frequency miner will automatically configure the frequency of the miner. 1 Go to ‘Miner Configuration’ tab, and the ‘Miner Link’ tab in order to configure the relevant settings. 2TH/s. 11VDC per hash board IC. Jun 12, 2024 · Yet, it is worth noting that the 14Th model can get too hot during operation and thus cannot consistently maintain the frequency it proclaims. 4 A Fan speed: Front: 6000 rpm, rear:4500 rpm Operating temperature Apr 2, 2019 · Miner cannot connect mining pools >. The L3+ is one of the most popula Jun 8, 2023 · Connect to Router: Use an Ethernet cable to connect the Antminer K7 to your router or network switch. Jul 17, 2014 · Code: The default IP address of the miner is 192. Experimenting with different configurations can help you find the optimal settings for your specific mining environment. zip is supported by Microsoft Windows only. When upgrading the fixed frequency miner, select the latest firmware corresponding to the hash rate to upgrade. If I add two circuit breakers instead of one then I can power up to six S17+ AntMiners. Frequency right now is base 381 with MH/S at 500. Operation altitude, m (3-1) ≤2000. Reloading firmware >. 10~90%. Key in the mining pool URL and miner name (under Worker). Note the hash power attained using the selected frequency. All other technical questions >. Miner cannot connect mining pools >. 2 Frequency Modification You are able to modify the frequency value through ‘Miner Configuration->Advanced Settings‘. To configure the server: click Setting marked below. 9. Please send me a notification to my e-mail when the new batch release. The indoor temperature is about 26℃ and about 20℃ at night. Consider using additional cooling solutions such as fans or liquid cooling systems if necessary. If you are using more than one PSU,power up the PSU connected to the controller AFTER you have powered up the other PSU(s). Page 12: Modifying The Frequency L3+ Server Installation Guide 4. Precautions for Connection between Power Supply and Miner. What do these temperatures mean >. May 12, 2019 · Ensure the Ethernet crystal head connector is plugged. Check here for the Setting-up for PSU. The related personnel shall be familiar with the basic miner maintenance methods, including system upgrade, reset, restore, SD card recovery. Some say I should use 8. If the user fails to use the product in accordance with the given instructions, specifications, and conditions provided, or change the function setting without BITMAIN's prior consent, BITMAIN will not be liable for any damage arising therefrom. 2. 5. We would like to show you a description here but the site won’t allow us. com and a. Clean the mining rig regularly to remove dust and debris that can obstruct airflow. 7 years ago. The Ant-Miner S9, the first version of which was released in 2016 and uses 16-nano meter chips, has become a standard in the industry among miners. A small number of miners may have low hash rate and instability issue after over frequency. The Antminer L3++ comes with an APW3-12-1600-B2 power supply unit, which has a conversion rate of 93%. Amidst this evolution, the Antminer S9 emerged as a […] Connect the network cable to the ETH port. I also made adjustments to one with a 1,930 watt power limit, but the results were less successful. ) We can get 740W total (185W per hash board) by Jan 19, 2023 · The Antminer L3+ is a dedicated mining hardware device from Bitmain that is optimized for mining Litecoin using the Scrypt hashing algorithm. To prevent the spread of viruses in the firmware, which can cause damage to the ANTMINER S19 series, the setting function of “Secure Boot” has been switched on and the “Root Authority” function has been disabled. . Note that we measured the power consumption at the wall, not relying on the firmware’s estimated power consumption to collect this data. 3. Operation altitude, m(3-1) ≤ 2000. If the user fails to use the product in accordance with the given instructions, specifications, and conditions provided, or change the function setting without BITMAIN's prior consent, BITMAIN will not be Jan 1, 2019 · So you set it to 9. Abnormal status: ”X” means that a certain chip is not working. Frequency and Voltage Adjustments: Some Antminer models allow you to adjust the frequency and voltage settings. Access the Miner Status tab next. Notes: 1. Tuning the hash boards to run on minimal speed and power can have the board operating at the edge of its ability to function. Caution: A mains socket-outlet that is earthed must be used to connect the equipment. Now you are almost ready to upload your files. Go into your advanced settings for the problem hash board and try lowering the frequency and upping the voltage to at least 9. The miner (all-in-one) cannot be turned on. Jul 1, 2021 · Setting Up the Pool. Fan is set to default silent mode and averages 1776rpm. Search for the miner’s IP. Preparing the ASIC. The miner's IP address will be displayed. Each hashboard must be powered by the same PSU to prevent possible damage Feb 4, 2022 · --anu-freq < arg > Set AntminerU1 /2 frequency in MHz, range 125-500 (default: 250. May 13, 2023 · Place your Antminer S9 in a well-ventilated area with adequate airflow. After flashing, check the advanced settings page and start at the lowest voltage setting and 400mhz. 3 Miner Link Connection 4. The server will adjust the fan speed automatically if the fan speed percentage has yet been selected. This is often measured in gigahashes per second (GH/s). How to set up a new S19j? A detailed tutorial to mine LTC with AntMiner (L3, L3+,L3++) Litecoin are mined using a cryptographic algorithm called Scrypt. For solo mining with CKPool, the URL typically looks like solo. 5M, hit "Save&Apply" And guess what, my once sick miner was now working at 662. Once you have your config, save it as cgminer. Currently supported devices are Bitmain’s Antminer S9, S9i, and S9j. For high power consumption, hash rate can increase by 20%+ (comparing to Antminer S9, 13. See full list on home-mining. I'm new mining. - 12 - Page 13: Monitoring Your Miner Antminer L3+, Worth Overclocking or Leave in Factory. The default frequency for the AntMiner L3+ is 384M; 5. 2 Moonlanders and 2 AntRouter R1s in a solo pool. Power Cord: C20 male to C13 connector 10A power cord ( Cord ). What You Need to Know before Using Miners: 1. Antminer L3 Installation Guide - Antminer Distribution Europe BV Jul 24, 2022 · Configure Your Antminer: Access your Antminer’s web interface again. The default frequency for the AntMiner S5 is 350M. Temperature lower or higher than normal >. 4v for every frequency. Connecting the Power Supply. Power up the miner and wait for the normal (green) light to start flashing before searching for the miner’s IP address. To maximize your mining performance with the Antminer L7, there are several optimization techniques you can employ. If you are getting too many, you may have your frequency set too high, as you are overloading that board. 4. Set the options according to the following table: Option Description Pool URL Enter the URL of your desired pool. (1-1) Caution: Wrong input voltage may probably cause server damaged. This manual mainly tells the related points involved in ANTMINER operation and maintenance. 44761V a chip. All models of S7 and before are fixed frequency machines. Power Consumption. The difference between the firmware of fixed-frequency miner and auto-frequency miner. Using V1. cy yd id bn qx lq jk re ip wd